KP1002A-7T
Input voltage | 220V/50Hz or 110V/60Hz |
Output voltage | AC 5.6KV |
Power | 50W |
Ion balance | ≤|±10V|(distance 300mm) |
Discharge time | ≤2S(distance 300mm) |
Working distance | 400×900mm |
Working temperature | 0ºC-50ºC |
Working humidity | <75% |
Fan air volume ≤5.1m3/min | 80-220CFM |
Noise | 49-55dB |
Ozone concentration | ≤ 0.03 ppm (distance150mm) |
Gross weight | 6kg |
Dimension | 600mm(L)*170mm(W)*125mm(H) |
Surface treament | Electrostic painting |
Testing condition | |||
Humidity:≤60% Testing voltage:1KV-100V Temperature:22ºC | |||
Distance | 300mm | 600mm | |
Decay time | Positive | 1.0s | 1.4s |
Negative | 1.0s | 1.5s | |
Offset voltage | Positive | +6v | +10v |
Negative | -7v | -9v |
* The test result by ME268A comprehensive electrostatic tester shall prevail.
* Test according to IEC - 61340-5-1 A 6.
* Test data may change with the surrounding temperature and humidity.
KP1002A-7T Generation 3th overhead 2-fan ionizing air blower is an antistatic device developed and produced by Kappar to eliminate static electricity on the surface of objects.
KP1002A-7T Generation 3th overhead 2-fan ionizing air blower is provided with wind power by two small fans, and the wind power can be adjusted in a large range by the speed control switch.
KP1002A-7T Generation 3th overhead 2-fan ionizing air blower is widely used in pharmaceutical manufacturing and assembly, electronic production and packaging, LED assembly line, semiconductor assembly production line and other industries.
1.Quickly eliminate static electricity.
2.Ion air flow covers a large area.
3.There is an ionization indicator.
4.There is a special ion emission needle cleaner.
5.If necessary, a cold air heating device can be installed.
6.The use of hanging installation can save space.
7.The fan has a good grounding protection function.
Input voltage | 220V/50Hz or 110V/60Hz |
Output voltage | AC 5.6KV |
Power | 50W |
Ion balance | ≤|±10V|(distance 300mm) |
Discharge time | ≤2S(distance 300mm) |
Working distance | 400×900mm |
Working temperature | 0ºC-50ºC |
Working humidity | <75% |
Fan air volume ≤5.1m3/min | 80-220CFM |
Noise | 49-55dB |
Ozone concentration | ≤ 0.03 ppm (distance150mm) |
Gross weight | 6kg |
Dimension | 600mm(L)*170mm(W)*125mm(H) |
Surface treament | Electrostic painting |
Testing condition | |||
Humidity:≤60% Testing voltage:1KV-100V Temperature:22ºC | |||
Distance | 300mm | 600mm | |
Decay time | Positive | 1.0s | 1.4s |
Negative | 1.0s | 1.5s | |
Offset voltage | Positive | +6v | +10v |
Negative | -7v | -9v |
* The test result by ME268A comprehensive electrostatic tester shall prevail.
* Test according to IEC - 61340-5-1 A 6.
* Test data may change with the surrounding temperature and humidity.
KP1002A-7T Generation 3th overhead 2-fan ionizing air blower is an antistatic device developed and produced by Kappar to eliminate static electricity on the surface of objects.
KP1002A-7T Generation 3th overhead 2-fan ionizing air blower is provided with wind power by two small fans, and the wind power can be adjusted in a large range by the speed control switch.
KP1002A-7T Generation 3th overhead 2-fan ionizing air blower is widely used in pharmaceutical manufacturing and assembly, electronic production and packaging, LED assembly line, semiconductor assembly production line and other industries.
1.Quickly eliminate static electricity.
2.Ion air flow covers a large area.
3.There is an ionization indicator.
4.There is a special ion emission needle cleaner.
5.If necessary, a cold air heating device can be installed.
6.The use of hanging installation can save space.
7.The fan has a good grounding protection function.